ADDISON UTP CAT6 Cabling-CAT6 UTP,FTP & SFTP Cable



CAT6 Cabling-CAT6 UTP FTP & SFTP Cable

Addison offers Cat6 cabling products including UTP CAT6 Cable and FTP CAT6 Cable and SFTP CAT6 Cable and FTP CAT6 Cable. They are mainly offered in 4 pair construction. The following are some specifications about the Cat6 cabling products:

Application

Ethernet Application

Utp Cat6 cable
UTP Cable CAT6

Protocols supported

10Base-T

10Base-TX,100 Base-VG

FDDI/CDDI 100Mbps

Token Ring 16Mbps

ATM 155Mbps

1000Base-T

Tested Frequency

Tested up to350MHz

Highlights

EL-PSFEXT AND PSACR results exceed by far the minimum proposed UTP Cable CAT6 limits

Delay Skew.LCL/LCTLand Coupling Attenuation in full compliance with proposed UTP CAT6 cabling standard

Applicable Standard

ISO/IECJTCI/SC25.WG3 UTP CAT6 Cabling

TIA/EIA568A UTP Cable CAT6


General Characteristics for UTP CAT6 Cabling

Impedance

100 ohmn+15%@1-100Mhz

Mutual Capacitance(Max)

42pF/m nom @1KHz wire to ground

capacitance Unbalance (Max)

1000pF/km @1KHz wire to ground

DC Resistance(Max)

(93.8Ohmn/km) Max

Resistance Unbalance (Max)

5%

Velocity Ratio(Nom)

UTP

FTP

STP

UTP Patch

FTP Patch

66%

78%

80%

66%

66%

Coupling Attenuation(Min)

As per individual technical specification

LCL (Min)

48-10 log (f)@1-300MHz

Propagation Delay

534+36(f)1/2 max @1-300MHz

Propagation Delay Skew

45n S/100m max @1-300MHz

Insulation Resistance

152MoHM Km min @500Vdc 20C

Above values are valid for non plenum/FRPVC/LSZH type)


Construction Matrix for UTP CAT6 Cabling

 

Type

UTP

UTP Patch Cable

FTP

FTP Patch Cable

 

4prs 23/24#

4prs 24#

4prs 23/24#

4prs 26#

Conductor

Material

Solid Plain Copper

Stranded Plain Copper

Solid Plain Copper

Stranded Plain Copper

 

Comnposition(No/MM)

1/0.55mm

7/0.2mm

1/0.5mm

7/0.16mm

 

Gauge

23/24AWG

24AWG

23/24AWG

26AWG

Insulation

Material
Plenum:FEP

Non-plenum:
PE
Plenum:FEP

Non-plenum:
PE
Plenum:FEP

Non-plenum:
PE
Plenum:FEP

Non-plenum:
PE
Plenum:FEP

 

Diameter(mm)

1.0

0.96

1.02

0.96

Screen

Material

NIL

NIL

Overal
screened

Overal
screened

Drain Wire

Material

NIL

NIL

1*0.4mm

7*0.16mm

Construction

No of pairs

4prs

4prs

4prs

4prs

Outer Sheath

Material

PVC/FRPVC/LSZH

PVC/FRPVC/LSZH

PVC/FRPVC/LSZH

PVC/FRPVC/LSZH

Outer Diameter

Diameter(mm)

6.5+0.2(4 pairs)

5.5+0.2(4 pairs)

6.0+0.2(4 pairs)

5.8+0.2(4 pairs)


Performance Matrix for UTP CAT6 Cabling

Frequ-
ency

PSACR
(dB/100m) Min

Return Loss
(dB) Min

FEXT
(dB) Min

ELFEXT
(dB/100m) Min

PSELFEXT
(dB/100) Min

 

STP
24#

FTP23#
/24#

FTP
23#

STP
24#

FTP23#
/24#

FTP
23#

STP
24#

FTP23#
/24#

FTP
23#

STP
24#

FTP23#
/24#

FTP
23#

STP
24#

FTP23#
/24#

FTP
23#

1

74

62

62

20

23

23

76

58

58

75

56

56

70

53

53

4

75.2

60.2

60.2

23

23

23

64

59.8

59.8

75

56

56

70

53

53

8

74.6

54.1

54.1

23

23

23

60

55.3

55.3

75

49.9

49.9

70

46.9

46.9

10

74.3

52

52

25

23

23

58.1

54

54

75

48

48

70

45

45

16

72.4

47.3

47.3

25

23

23

54.1

51.5

51.5

75

43.9

43.9

70

40.9

40.9

20

71.5

45

45

25

23

23

53.1

50.5

50.5

75

42

42

70

39

39

31.25

70.2

39.9

39.9

23

23

23

51.8

48.8

48.8

75

38.1

38.1

70

35.1

35.1

62.5

64.5

30.6

30.6

21.5

23

23

50.8

47.6

47.6

75

32.1

32.1

70

29.1

29.1

100

60.1

23.1

23.1

20

23

23

51

47.9

47.9

70

28

28

65

25

25

155

44.6

14.8

14.8

18.7

21.1

21.1

53.2

49.5

49.5

65

24.2

24.2

60

21.2

21.2

175

42.9

12.3

12.3

18.4

20.6

20.6

54.2

50.2

50.2

60

23.1

23.1

55

20.1

20.1

200

40.8

9.3

9.3

18

20

20

55.2

51.1

51.1

60

22

22

55

19

19

250

37

4

4

17.3

19

19

57.2

53.1

53.1

55

20

20

50

17

17

300

34.1

-0.8

-0.8

17

18.2

18.2

59.2

55.1

55.1

53

18.5

18.5

48

15.5

15.5

350

32

-5.2

-5.2

16.5

17.6

17.6

61.2

57.1

57.1

50

17.1

17.1

45

14.1

14.1

(Above values are valid for non plenum/FRPVC/LSZH type)
(All values are worst case. Tests were set up in accordance with TIA/EIA-568A.The values shown are typical and subject to change)


Frequ-
ency

PSACR
(dB/100m) Min

Return Loss
(dB) Min

FEXT
(dB) Min

ELFEXT
(dB/100m) Min

PSELFEXT
(dB/100 Min)

 

STP
24#

FTP23#
/24#

FTP
23#

STP
24#

FTP23#
/24#

FTP
23#

STP24#

FTP23#
/24#

FTP
23#

STP
24#

FTP23#
/24#

FTP
23#

STP
24#

FTP23#
/24#

FTP
23#

1

74

62

62

20

23

23

76

58

58

75

56

56

70

53

53

4

75.2

60.2

60.2

23

23

23

64

59.8

59.8

75

56

56

70

53

53

8

74.6

54.1

54.1

23

23

23

60

55.3

55.3

75

49.9

49.9

70

46.9

46.9

10

74.3

52

52

25

23

23

58.1

54

54

75

48

48

70

45

45

16

72.4

47.3

47.3

25

23

23

54.1

51.5

51.5

75

43.9

43.9

70

40.9

40.9

20

71.5

45

45

25

23

23

53.1

50.5

50.5

75

42

42

70

39

39

31.25

70.2

39.9

39.9

23

23

23

51.8

48.8

48.8

75

38.1

38.1

70

35.1

35.1

62.5

64.5

30.6

30.6

21.5

23

23

50.8

47.6

47.6

75

32.1

32.1

70

29.1

29.1

100

60.1

23.1

23.1

20

23

23

51

47.9

47.9

70

28

28

65

25

25

155

44.6

14.8

14.8

18.7

21.1

21.1

53.2

49.5

49.5

65

24.2

24.2

60

21.2

21.2

175

42.9

12.3

12.3

18.4

20.6

20.6

54.2

50.2

50.2

60

23.1

23.1

55

20.1

20.1

200

40.8

9.3

9.3

18

20

20

55.2

51.1

51.1

60

22

22

55

19

19

250

37

4

4

17.3

19

19

57.2

53.1

53.1

55

20

20

50

17

17

300

34.1

-0.8

-0.8

17

18.2

18.2

59.2

55.1

55.1

53

18.5

18.5

48

15.5

15.5

350

32

-5.2

-5.2

16.5

17.6

17.6

61.2

57.1

57.1

50

17.1

17.1

45

14.1

14.1

(Above values are valid for non plenum/FRPVC/LSZH type)
(All values are worst case.Tests were set up in accordance with TIA/EIA-568A.The values shown are typical and subject to change)


Ordering Information for UTP CAT6 Cabling

UTP Cable CAT6,
CM/CMR/CMP/FRPVC/LSZH/PUR,23/24AWG

SFTP Cable CAT6,
CM/CMR/CMP/FRPVC/LSZH/PUR,23/24AWG

No.of Pair

Pair No.

Description

No.of Pair

Pair No.

Description

4

AD-CAT6UTP4PCM23/24

UTP Cable Cat6 4 Pairs,CM(Non-Plenum Grade)

4

AD-CAT6SFTP4PCM24A

SFTP Cable Cat6 4 Pairs,CM(Non-Plenum Grade)

4

AD-CAT6UTP4PCMR23/24

UTP Cable Cat6 4 Pairs,CMR(Riser Grade)

4

AD-CAT6SFTP4PCMR24A

SFTP Cable Cat 6 4 Pairs,CMR(Riser Grade)

4

AD-CAT6UTP4PCM23/24

UTP Cable Cat6 4 Pairs,CMP(Plenum Grade)

4

AD-CAT6SFTP4PCM24A

SFTP Cable Cat 6 4 Pairs,CMP(Plenum Grade)

4

AD-CAT6UTP4PFR23/24*

UTP Cable Cat6 4 Pairs,FRPVC

4

AD-CAT6SFTP4PFR24A*

SFTP Cable Cat6 4 Pairs,FRPVC

4

AD-CAT6UTP4PLH23/24**

UTP Cable Cat 6 4 Pairs,LSZH

4

AD-CAT6SFTP4PLH24A**

SFTP Cable Cat6 4 Pairs,LSZH

4

AD-CAT6UTP4PPUR23

UTP Cable Cat 6 4 Pairs,PUR

4

AD-CAT6SFTP4PPUR23A

SFTP Cable Cat6 4 Pairs,PUR

     

4

AD-BC-MNSFTP23A

Matrix LAN SFTP cable


STP CAT6 Patch Cable,
CM/CMR/CMP/FRPVE/LSZH,26AWG

STP CAT6 Patch Cable,
CM/CMR/CMP/FRPVE/LSZH,26AWG

No.of
Pair

Pair No.

Description

No.of
Pair

Pair No.

Description

4

AD-CAT6STP4PCM24A

STP Cable Cat6 4 Pairs,CM(Non-Plenum Grade)

4

AD-CAT6STP4PCM26A

STP Cable Cat6 4 Pairs,CM(Non-Plenum Grade)

4

AD-CAT6STP4PCMR24A

STP Cable Cat6 4 Pairs,CMR(Riser Grade)

4

AD-CAT6STP4PCMR26A

STP Cable Cat6 4 Pairs,CMR(Riser Grade)

4

AD-CAT6STP4PCM24A

STP Cable Cat6 4 Pairs,CMP(Plenum Grade)

4

AD-CAT6STP4PCM26A

STP Cable Cat6 4 Pairs,CMP(Plenum Grade)

4

AD-CAT6STP4PFR24A*

STP Cable Cat6 4 Pairs,FRPVC

4

AD-CAT6STP4PFR26A*

STP Cable Cat6 4 Pairs,FRPVC

4

AD-CAT6STP4PLH24A**

STP Cable Cat6 4 Pairs,LSZH

4

AD-CAT6STP4PLH26A**

STP Cable Cat6 4 Pairs,LSZH

*FRPVC material may comply with IEC332-1,IEC332-3A/B/C,When ordering FRPVC rade,Fire retardancy standard has to be specified.Please refer to pae 21-22 for more detailed information.
**LSZH material may comply with IEC332-1,IEC332-3A/B/C,When ordering LSZH grade, Smoke Density,Acid Gas Emission,Corrosive Gas Emission,Toxicity Index,OxygenIndex AND \Flammability Temperature Index together with fire retardancy standard have to be specified.Please refer to page 21-22 for more detailed information.
***Addison offers full cabling line such as utp cat5 cable | utp cat5e cable | utp cat6 cable | utp cat7 cable etc.If you want to learn more, please read utp cable cat6's FAQ.

 

Cabling System Manufacturer and a Cabling Solution Provider


Company Profile
| Distribution Policy | Products | Business Partners | Contact | links | link us | FAQ | News | site map | download
Copyright © 1991-2004 Addison Technology Ltd
webmaster@addison-tech.com