CCL-VATC-02 Cable |
Product Name/Code : CCL-VATC-02 Cable |
Electrical Performance |
Application : |
Electrical Characteristics: |
For communication and signal control systems. |
Frequency |
Attenuation |
Reference Standard |
(MHz) |
(dB/100m) |
Customer's sample spec. and the general standard |
47 |
4.30 |
100 |
6.00 |
Cable Construction |
230 |
8.90 |
Center Conductor |
Bare Copper |
300 |
10.20 |
Dia.(mm) |
1/1.13 |
400 |
11.80 |
Insulation |
Solid PE |
800 |
17.50 |
Nom. Thickness(mm) |
1.8 |
860 |
17.90 |
Insulation Dia. (±0.03mm) |
4.8 |
1000 |
19.50 |
Bonded Al/Polyester Foil |
. |
1350 |
23.00 |
Coverage Area(%) |
>=100 |
1750 |
26.3 |
Tinned Copper Braid Shield |
. |
2050 |
28.9 |
Construction |
16/ 6/0.12 |
2150 |
29.5 |
Coverage Area(%) |
>=60 |
2400 |
31.3 |
Jacket |
PVC |
. |
. |
Nom. Thickness(mm) |
0.9 |
Operating Temperature( ? ) |
60 |
Cable Dia.(±0.10mm) |
6.8 |
Capacitance(pF/m) |
52 |
Jacket Compound |
PVC/LSF/LSOH |
Impedance(+/-3 O ) |
75 |
Core Identification/Color Code |
According to customer request |
Velocity ratio (+/-5%) |
83 |
Bending Radius |
6 x Overall Diameter |
. |
. |
Temperature Rating |
70 ? |
. |
. |
Voltage Rating |
300/500V |
. |
. |
Fire Performance |
. |
. |
. |
Flame Propagation Test to IEC 60332 Part 1 and Part 3
Determination of the amount Halogen Acid Gas to IEC 60754 Part 1
Smoke Density Test to IEC 61034
Oxygen Index Test to BS 2863 or ISO 4589-2
Temperature Index Test to BS 2782 or ISO 4589-3
Fire Resistant Test to IEC 60331-24 |
|
|