RG11 Cable

¡ò Application:
For communication and signal control systems.

¡ò Reference Standard:
Customer's sample spec. and the general standard.

¡ò Cable Construction:

Cable Construction

Center Conductor

Bare Copper/CCS
Dia.: 1/1.63

Insulation

Foam Skin PE
Nom. Thickness(mm): 2.81
Insulation Dia. (¡À0.03mm): 7.25

Bare Copper Braid Shield

Construction: 16/ 7/0.12
Coverage Area(%):>=95

Jacket

PVC
Nom. Thickness(mm): 1.07
Cable Dia.(¡À0.10mm): 10.30

Jacket Compound

 

PVC/LSF/LSOH
Core Identification/Color Code: According to customer request
Bending Radius: 6xOverall Diameter
Temperature Rating: 70 ¡æ
Voltage Rating: 300/500V

Fire Performance

Flame Propagation Test to IEC 60332 Part 1 and Part 3
Determination of the amount Halogen Acid Gas to IEC 60754 Part 1
Smoke Density Test to IEC 61034
Oxygen Index Test to BS 2863 or ISO 4589-2
Temperature Index Test to BS 2782 or ISO 4589-3
Fire Resistant Test to IEC 60331-24

Electrical Performance
Electrical Characteristics:

Frequency(MHz)

Attenuation(dB/100m)

50

3.3

100

5.0

200

7.0

400

9.0

700

13.0

900

14.6

1000

18.5

Operating Temperature( ¡æ )

60

Capacitance(pF/m)

56

Velocity ratio (+/-5%)

78

 Impedance(+/-3 ¦¸ )

75