Product List


Open Matrix System(OMS)


Data & Fiber Optic Cables


Connecting Hardware


Real Time Patching System


Cabling Solutions


Fire Performance Standard
 
E-shop
FAQ
Download
Contact
 
 
HomeProduct DispalyNavigation 
Product Profile  
 
                   
     
Product name: Fiber Optic Patch cord
           
Keywords: Addison Fiber Optic Patch cord
 
               
    Product Picture    
   
  fiber optic adapter fiber optic connectors optic fiber patch cord
     
Product Introduction
Optic Fiber Patch Cord

Fiber Patch Cords
◎ Basic Features:
☆ Simplex or duplex fibers for selection.
☆ Different fiber connectors for selection.
☆ Ferrule Material: Ceramic, stainless steel, polymer
☆ Outer Jacket: PVC, FRPVC, LSZH
☆ Connector Types: ST/SC/FC/SMA905 or 906/D4/BICONIC/FDDI/MTRJ/LC/E2000/ DIN/ EC
☆ FC, SC, ST, LC, MU connectors offered in either PC, UPC, APC polishing.
☆ Complying to applicable standard such as TIA/EIA-568 and IEC 874-1.
☆ Used for Ethernet, fiber optic system, video transmission, CATV and cable TV etc.
Technical Parameters:
☆ Cladding Diameter: 125μm
☆ Core Diameter: 50/62.5μm (multimode); 9/125μm (single-mode)
☆ Tensile Strength: 15Kgf (except for 0.9mm)
☆ Diameter: 3mm /2mm
☆ Minimum Bending Radius: 10 x Overall Diameter
☆ Working Temperature: -40℃ ~ +75℃
☆ Storage Temperature: -50℃ ~ +85℃
☆ Minimum Insertion Life Cycles: 1000 times
☆ Single mode fiber patch cord (in general): Insertion Loss ≤ 0.3 dB (APC/UPC); Return Loss≥50dB (UPC); ≥ 60 dB (APC)
☆ MTRJ single mode fiber patch cord: Insertion loss ≤ 0.5 dB; Return Loss ≥ 35 dB
☆ Multimode fiber patch cord (in general):
Insertion Loss ≤ 0.3 dB (PC); ≤ 0.3 dB (UPC); ≤ 0.3 dB (APC)
Return Loss ≥ 35 dB (PC); ≥ 50 dB (UPC); ≥ 60 dB (APC)
☆ MTRJ multimode fiber patch cord: Insertion loss ≤ 0.5 dB; Return Loss≥20 dB
☆ Change on insertion loss for mechanical characteristics:
Interchangeability: 0 2dB.
Repeatability (Insertion: 1,000 times): 0.2dB
Anti pulling load: 0.2dB (10Kg tension/3.0mm fiber)
Anti Vibration: 0.2dB (Vibration: 10-58Hz; Amplitude: 1.5mm, 10Hz/min, 2 hrs)
☆ Change on insertion loss for environmental characteristics:
Temperature Cycle: 0.2dB (-40℃ ~ +80℃ 5 cycles)
High Temperature Test: 0.2dB (High Temperature: 85℃,100 hrs)
Low Temperature Test: 0.2dB (Low Temperature:-40℃, 100 hrs)
Humidity Test: 0.2dB (65℃, 93% relative humidity, 100 hrs)
Product Highlights:
☆ Using extra high precision ceramic ferrule with small concentricity error and core diameter, better insertion loss and return loss can be achieved for optimized transmission performance.
☆ All fiber surface parameters such as the apex offset, fiber height and radius of curvature comply to IEC standard.
☆ Besides attenuation and back reflection testing, cords are also checked by interferometer for fiber surface parameters, including radius of curvature, apex offset and fiber heights for different FC, ST, SC, LC and MU connector types.
☆ Simplex, duplex and fan-outs can be offered.
☆ Different jackets such as PVC and LSZH grade available for selection.
☆ Low insertion loss and high return loss, with excellent interchangeability and repeatability.
☆ Durablity, damp-proofing, resistant to coupling stress, high pull tension and adaptation to different harsh environment such as dampness, extreme temperature, impact and vibration in accordance to ANSI/TIA and ISO/IEC standard.
☆ Environmentally stable, meeting Telcordia requirement.

ST, SC, FC (PC/UPC/APC) Fiber Patch Cord
  Basic Features:
☆ PC, UPC or APC polishing for selection.
☆ Low insertion loss and high return loss.
☆ The SC connectors for SC-SC fiber patch cords are of push pull design, being fit for 3.0mm fiber patch cords.
☆ The ST connectors for ST-ST fiber patch cords are of metal ring design, being fit for 3.0mm fiber patch cords.
☆ The ST connectors of LC-ST fiber patch cords are of metal ring design, being fit for 2.0mm fiber patch cords.
☆ The SC connectors of LC-SC fiber patch cords are of push pull design, being fit for 2.0mm fiber patch cords.
☆ Significant margin over ANSI/TIA/EIA 568 standard.
☆ Fiber Surface Parameters
Radius of Curvature: 5~12cm(APC); 7~25cm(PC)
Apex Offset: ≤ 100μm
Fiber Height: +100 ~ -100 nm
Deviation Angle: 8°± 0.3°
Technical Parameters:

 

PC

UPC

APC

Simplex

Duplex

Insertion Loss

≤0.3dB

≤0.3dB

≤0.3dB

Return Loss

≥45dB

≥35dB

≥50dB

≥60dB

Working Temperature

-20℃~70℃

-20℃~70℃

-20℃~70℃

Storage Temperature

-25℃~80℃

-25℃~80℃

-25℃~80℃

Maximum change in Insertion Loss with repeated insertion

0.1dB

0.1dB

0.1dB

Maximum Insertion /Withdrawal

≥1000

≥1000

≥1000

 

ST-ST Duplex Patch Cord                 SC-SC Duplex Patch Cord               FC-FC Simplex Patch Cord

MTRJ, MU, LC Fiber Patch Cords
Basic Features:
☆ Push-pull connection, fast and reliable.
☆ Low insertion loss and high return loss.
☆ Being compact and light weight, it can provide high-density installation.
☆ 1.25um ceramic ferrule fit for both single and multimode cables.
☆ MTRJ connector/adaptors are fit for duplex zip and round cords together with ribbon fiber cables.
☆ LC connector/adaptors are fit for simplex /duplex zip cord and MU connector /adaptor is fit for simplex zip cord.
☆ Used for different fiber optic system, fiber optic connector, CATV and testing equipment etc.

Technical Parameters:(LC/MU)

 

PC

UPC

Simplex

Duplex

Insertion Loss

≤0.4dB

≤0.4dB

Return Loss

≥45dB

≥35dB

≥50dB

Working Temperature

-20℃~70℃

-20℃~70℃

Storage Temperature

-25℃~80℃

-25℃~80℃

Maximum change in Insertion
Loss with repeated insertion

0.1dB

0.1dB

Maximum Insertion /Withdrawal

≥1000

≥1000

LC Simplex                       MU Simplex

Technical Parameters:(MTRJ)                           

 

PC

UPC

Simplex

Duplex

Insertion Loss

≤0.5dB

≤0.6dB

Return Loss

≥35dB

≥20dB

≥4.5dB

Working Temperature

-20℃~70℃

-20℃~70℃

Storage Temperature

-25℃~80℃

-25℃~80℃

Maximum change in Insertion
Loss with repeated insertion

0.1dB

0.1dB

Maximum Insertion /Withdrawal

≥1000

MTRJ Simplex                    MTRJ Duplex

 ≥1000

SMA, FDDI Fiber Patch Cords
Basic Features:
☆ SMA connectors are interchangeable and come with good surface polishing.
☆ FDDI connectors are equipped with built-in identification labels.
☆ FDDI connectors meet ANSI3T95 FDDI PMD standard.
☆ SMA connectors are suitable for use in LAN and low speed system test.
☆ FDDI connectors are suitable for duplex system, FDDI backbone network and IEEE802.4 Token Bus.

Technical Parameters:(SMA, FDDI)

 

SMA

FDDI

Insertion Loss

≤0.3dB

≤0.3dB

Return Loss

≥35dB

≥4.5dB

Working Temperature

-40℃~80℃

-40℃~80℃

Storage Temperature

-55℃~85℃

-55℃~85℃

Maximum change in Insertion
Loss with repeated insertion

0.2dB

0.2dB

Maximum Insertion /Withdrawal

≥1000

SMA Simplex           

FDDI Duplex

 ≥1000

◎ Ordering Information:


Part No.

Description

AD-ST/ST-D9M001CON-II-JJ

Single Mode ST/ST-ST/ST Duplex 1 Meter PVC Fiber Patch Cord

AD-ST/ST-D9M003CON-II-JJ

Single Mode ST/ST-ST/ST Duplex 3 Meter , PVC Fiber Patch Cord

AD-ST/ST-S9M001CON-II-JJ

Single Mode ST/ST Simplex 1 Meter PVC Fiber Patch Cord

AD-ST/ST-S9M003CON-II-JJ

Single Mode ST/ST Simplex 3 Meter , PVC Fiber Patch Cord

AD-SC/SC-D6M001CON-II-JJ

Multimode 62.5/125 μm SC/SC-SC/SC Duplex 1 Meter PVC Fiber Patch Cord

AD-SC/SC-D6M003CON-II-JJ

Multimode 62.5/125 μm SC/SC-SC/SC Duplex 3 Meter PVC Fiber Patch Cord

AD-SC/SC-S6M001CON-II-JJ

Multimode 62.5/125 μm SC-SC Simplex 1 Meter PVC Fiber Patch Cord

AD-SC/SC-S6M003CON-II-JJ

Multimode 62.5/125 μm SC-SC Simplex 3 Meter PVC Fiber Patch Cord

AD-ST/ST-D5M001CON-II-JJ

Multimode 50/125 μm ST/ST-ST/ST Duplex 1 Meter PVC Fiber Patch Cord

AD-ST/ST-D5M003CON-II-JJ

Multimode 50/125 μm ST/ST-ST/ST Duplex 3 Meter , PVC Fiber Patch Cord

AD-ST/ST-S5M001CON-II-JJ

Multimode 50/125 μm ST-ST, Simplex 1 Meter PVC Fiber Patch Cord

AD-ST/ST-S5M003CON-II-JJ

Multimode 50/125 μm ST-ST, Simplex 3 Meter PVC Fiber Patch Cord

AD-ST/ST-D4M001CON-II-JJ

OM3 Multimode 50/125 μm ST/ST-ST/ST Duplex 1 Meter , PVC Fiber Patch Cord

AD-ST/ST-D4M003CON-II-JJ

OM3 Multimode 50/125 μm ST/ST-ST/ST Duplex 3 Meter , PVC Fiber Patch Cord

AD-ST/ST-S4M001CON-II-JJ

OM3 Multimode 50/125 μm ST-ST, Simplex 1 Meter , PVC Fiber Patch Cord

AD-ST/ST-S4M003CON-II-JJ

OM3 Multimode 50/125 μm ST-ST, Simplex 3 Meter , PVC Fiber Patch Cord

AD-SC/SC-D4M001CON-II-JJ

OM3 Multimode 50/125 μm SC/SC-SC/SC Duplex 1 Meter PVC Fiber Patch Cord

AD-SC/SC-D4M003CON-II-JJ

OM3 Multimode 50/125 μm SC/SC-SC/SC Duplex 3 Meter PVC Fiber Patch Cord

AD-SC/SC-S4M001CON-II-JJ

OM3 Multimode 50/125 μm SC-SC Simplex 1 Meter , PVC Fiber Patch Cord

AD-SC/SC-S4M003CON-II-JJ

OM3 Multimode 50/125 μm SC-SC Simplex 3 Meter , PVC Fiber Patch Cord

AD-ST-S4M001CON-II-JJ

OM3 Multimode 50/125 μm ST, Simplex 1 Meter PVC Pigtail

AD-SC-S4M001CON-II-JJ

OM3 Multimode 50/125 μm SC Simplex 1 Meter PVC Pigtail

AD-ST-S9M001CON-II-JJ

Single Mode ST Simplex 1 Meter PVC Pigtail

AD-SC-S9M001CON-II-JJ

Single Mode SC Simplex 1 Meter PVC Pigtail

AD-ST-S6M001CON-II-JJ

Multimode 62.5/125 μm ST Simplex 1 Meter PVC Pigtail

AD-SC-S6M001CON-II-JJ

Multimode 62.5/125 μm SC Simplex 1 Meter PVC Pigtail

AD-ST-S5M001CON-II-JJ

Multimode 50/125 μm ST Simplex 1 Meter PVC Pigtail

AD-SC-S5M001CON-II-JJ

Multimode 50/125 μm SC Simplex 1 Meter PVC Pigtail

◎ Ordering Code:
AD-AB-C-D-EFFF-G-HH-II-JJ
**AB**Left/Right Connector Types
ST=ST; SC=SC; FC=FC; SMA905=SMA905; SMA906=SMA906; FD=FDDI; MT=MTRJ; LC=LC (FC, SC, ST, LC, MU Connector: PC, UPC, APC for selection)
**C**Cable Type Family
S=Simplex; D=Duplex Zip
**D**Fiber Types
9=Single-mode 9/125μm 6=Multimode 62 5/125 μm; 5=Multimode 50/125μm; 4=Multimode 50/125 μm(OM3)
**EFFF**Length
F003 =3 Feet, F005 =5 Feet, F007 =7 Feet; M001 =1 Meter, M002 =2 Meter, M003 =3 meter
**G**Ferrule Types
C=Ceramic; S= Stainless Steel; P= Polymer
**HH** Fire Performance Rating
ON = Normal PVC, OFN grade; OR = FRPVC, OFNR Riser Grade; OP=FEP, OFNP Plenum Grade; FR=FRPVC, to IEC 60332 -3C; LH= LSZH grade to IEC 60754-1, IEC 61034 P1/2
**II**Jacket colors
01-Yellow; 02-Blue; 03-Green; 04-White; 05-Orange; 06-Purple; 07-Red; 08-Grey
**JJ**Fiber Outer Diameter
09=ф0.9mm; 20=ф2.0mm; 30=ф3.0mm

          [1] [2] [3] [4] [5]